replacing a ceiling light fitting Replace Recessed Light With a Pendant Fixture, HGTV 10 Brilliant Replacing A Ceiling Light Fitting Galleries

10 Brilliant Replacing A Ceiling Light Fitting Galleries

Related photos in this project:

Other recommended ideas:

Replace Recessed Light With A Pendant Fixture, HGTV - Double-check the energy is off and run a spur cable from an current rose on the circuit. This connects its brown core to the primary circuit lives, its blue middle to the primary circuit neutrals and its earth to the earth terminal. At the brand new light position, connect its brown core to the imperative financial institution of terminals (which is probably marked 'loop') and its blue middle to the impartial terminal. Also, connect the earth to the earth terminal, adding inexperienced/yellow sleeving. Whichever sort of wiring you have got, you may be able to run the transfer cable back to the present transfer role. This replaces the authentic one-gang transfer with a -gang unit, and gives you a neater installation.

Subsequent, run one length of 1mm² two-center-and-earth cable to the brand new mild, and another to the transfer. Join the brown switch middle to the circuit lives, its earth to the circuit earths and its blue middle to the fourth terminal. Then add a period of brown % electric sleeving to this middle to expose it is able to be live. Your first undertaking is to discover what circuit type you've got: junction field or loop-in. With the electricity turned off, dispose of your ceiling rose cowl. You might not be able to tell from the layout of the rose - as a substitute, you'll need to remember the cables coming into it. If there may be most effective one cable then you definately have a junction-box wiring; if there are two or 3, then you have a loop-in system. If a unmarried pendant fitting isn't providing you with enough mild, you may upload another managed by means of the same transfer without an excessive amount of hassle. The one limiting issue is the variety of lighting shops already powered via the circuit - so don't danger overloading it.

With either form of wiring, you have a further choice. You can connect a 3-terminal junction container into the main circuit cable, and run a spur from there to a loop-in rose with its own switch cable. Unscrew the rose base from the ceiling and push the cable back thru. Above the ceiling, join the cable to a 3-terminal junction container. Then run a period of 1mm² -center-and-earth cable from your new mild rose.