How To Wire A, Light Switch From An Existing Outlet - A way to twine an attic electrical outlet and mild: a new junction container is stressed for the switch controlled electric outlet for the attic mild after getting rid of the antique mild transfer and wiring. This mission is sustained from the uncovered paintings cover junction field project. Also see part 1 for the assignment introduction.

Having proven the wiring and mild switch operation is correct, i shutoff the circuit breaker , then hooked up the uncovered paintings cowl to the metallic junction field. The extension wire for the air handler uv remedy light is plugged into the hole here:.

After completing the junction box wiring connections, mount the electrical outlet and light switch to the exposed work cowl as shown inside the previous undertaking. Then lightly fold the wires into the junction container in order no longer to kink or pinch the wires. The exposed work cover may be set up to the junction field now, however i left it open until i confirm the receptacle wiring, mild switch and transfer controlled outlet hooked up at the rafter collar tie… simply in case i made mistake and had to accurate the wiring.

The road-side nm-b 14/2 wires are fed through the 3/eight″ nm cable clamp into the junction box, the box is positioned numerous inches lower on the 2×4 framing via attic stairway to provide at the least 6 inches of wires within the field, that is determined through the length of the “short” ground twine. The junction field bracket is fixed to the two×4 framing with pan-head timber screws.

I have to take away it the vintage electrical box due to the fact the ground wire is simply too quick to make a proper pigtail connection. The electrician twisted and crimped the road- and cargo side floor wires collectively, cut off floor wires within the field, then used a steel crimp sleeve to attach the receptacle ground wire, that's a contravention of nec three hundred.14. Per nec three hundred.14, all conductors need to increase as a minimum 6 inches inside the container and at the least 3 inches past the field. Otherwise, the constructing inspector will flag it and received’t sign-off on the electric permit.